We participated to the following projects:
- Projet VIA-Qualité « Ventilation and indoor air quality in single-family houses: en route towards quality ventilation and indoor air » – Laureate of CORTÉA call for proposals « Knowledge, reduction at source and treatment of emissions in the air, Edition 2012-2013.
- Projet PROMEVENT « Improving Ventilation System Measurement Protocols » - Laureate of Ademe call for proposals « Towards responsible buildings at horizon 2020 – Edition 2014 ».
We co-organised the following events:
- AIVC annual conferences since 2011. See the 2017 conference website : http://www.aivc2017conference.org
- AIVC workshops since 2011 (1 to 2 par an). http://www.aivc.org/events/workshop/
We published the following papers:
Title, hyperlink | Year | Authors |
---|---|---|
Airtightness impact on energy needs and airflow pattern: A numerical evaluation for mechanically ventilated dwellings in France. International Journal of Ventilation. Vol. 15, Issue 2. | 2016 | Richieri, F., Moujalled, B., Salem, T. Carrié, F.R. |
Mettre en oeuvre une démarche pour améliorer la qualité de l’air intérieur en maisons individuelles. Guide pratique à destination des constructeurs de maisons individuelles. Projet VIA-Qualité. Rapport Cerema, Juin 2016. | 2016 | Carrié, F.R., Charrier, S., Guyot, G. Jobert, R. |
Uncertainties in building pressurisation tests due to steady wind. Energy and Buildings. 116: 656-665. https://doi.org/10.1016/j.enbuild.2016.01.029 | 2016 | Carrié, F.R. and Leprince, V. |
Model error due to steady wind in building pressurization tests. In proceedings of the 35th AIVC conference, Poznań, Poland, 24-25 September 2014. pp. 770-777. ISBN: 2-930471-44-1. | 2014 | Carrié, F.R. and Leprince, V. |
Temperature and pressure corrections for power-law coefficients of airflow through ventilation system components and leaks. In proceedings of the 35th AIVC conference, Poznań, Poland, 24-25 September 2014. pp. 778-785. ISBN: 2-930471-44-1. | 2014 | Carrié, F.R. |
CONFINE: an airtightness level calculation tool for people’s protection in case of accidental toxic release. WIT Transactions on Information and Communication Technologies, Vol 44, doi:10.2495/ RISK120281 | 2012 | Guyot, G., Carrié, F.R. |
Shelter in place strategy: CONFINE, an airtightness level calculation tool to protect people against accidental toxic releases. 32nd AIVC Conference "Towards Optimal Airtightness Performance", Brussels, Belgium, 12-13 October 2011 | 2011 | Guyot, G., Gentilhomme, O., Carrié, F.R. |